Learning Library · Amateur radio · 1
Transmitter power, dBm, and attenuators
A 100 W transmitter puts out +50 dBm. A spectrum analyzer's input is damaged at around +30 dBm. Those 20 dB are the difference between a measurement and a repair, so before a radio goes anywhere near an analyzer, work out the attenuation in dB and the power the attenuator has to absorb.
Top: the signal path. The attenuator glows with the power it turns into heat. Bottom: levels in dBm. The red line is the analyzer's maximum continuous RF input; the green band is 20 dB or more below it.
Watts to dBm
dBm is power relative to one milliwatt. Every 10 dB is a factor of ten, every 3 dB roughly a factor of two. Attenuators are rated in dB, so once the transmitter is in dBm the level at the analyzer is a subtraction.
| Power | dBm | Voltage (RMS, 50 Ω) |
|---|---|---|
| 1 mW | 0 dBm | 224 mV |
| 1 W | +30 dBm | 7.07 V |
| 5 W (handheld) | +37.0 dBm | 15.8 V |
| 100 W | +50 dBm | 70.7 V |
| 1,500 W | +61.8 dBm | 274 V |
Two numbers, not one
The attenuation decides what reaches the analyzer. The attenuator's power rating decides whether the attenuator survives: a 40 dB pad on a 100 W transmitter passes 10 mW and turns the other 99.99 W into heat. A small SMA attenuator rated for 2 W will not take that, so the first stage must be a power attenuator or a dummy load with a sampling port, with smaller pads after it.
UNI-T's ratings, from the datasheets: the UTS3000T+ series takes up to +33 dBm continuous RF for 3 minutes and the UTS3000A series up to +30 dBm, both with the analyzer's internal input attenuation above 20 dB, and 50 V DC on either. The rating is a damage limit, not a working level. Keeping the strongest signal 20 dB or more below it also keeps the analyzer's own mixer out of compression, so what you see is the transmitter and not the analyzer.
Try this
- Set 100 W and 40 dB. The analyzer sees +10 dBm, 23 dB below the UTS3000T+ rating, and the attenuator has to absorb 99.99 W.
- Set 5 W, the output of a typical handheld, with no attenuator. +37.0 dBm is over the rating on both analyzers. Even a handheld needs a pad.
- Set 1,500 W and 40 dB. +21.8 dBm is inside the rating with only 11.2 dB to spare. Add 10 dB more.
Two habits save analyzer inputs. Set the analyzer's reference level and input attenuation before keying, and key the transmitter at low power first, then raise it while watching the level. A DC block on the input protects against the DC on some transmitter outputs and bias tees.
Measure the transmitter, not the damage. Spectrum analyzers with a tracking generator, from 1.5 GHz.
Shop UNI-T spectrum analyzersUNI-T Learning Library. Design. Debug. Deploy.™