An SWR meter, a return-loss reading on a network analyzer, and the reflected-power needle all describe the same thing: how much of the transmitter's power the antenna sends back. Move the SWR and watch every one of them change together.
The voltage along the coax, radio on the left, antenna on the right. The yellow wave moves; the blue curves are the envelope it stays inside, the standing wave. Coax loss makes the ripple shrink toward the radio.
One quantity, four names
Γ, the reflection coefficient, is the fraction of the voltage that comes back. SWR, the standing wave ratio, is the ratio of the highest to the lowest voltage along the line. Return loss is how far below the forward power the reflection is, in dB, which is what a network analyzer's S11 trace shows. A purely resistive load of 50 × SWR or 50 ÷ SWR ohms gives that SWR on a 50 Ω line.
| SWR | Return loss | Power reflected | Mismatch loss |
|---|---|---|---|
| 1.2 | 20.8 dB | 0.8 % | 0.04 dB |
| 1.5 | 14.0 dB | 4.0 % | 0.18 dB |
| 2.0 | 9.5 dB | 11.1 % | 0.51 dB |
| 3.0 | 6.0 dB | 25.0 % | 1.25 dB |
Why the radio's meter flatters the antenna
The reflected wave travels through the coax twice, so it loses twice the cable's one-way loss before it reaches the meter at the radio. A lossy feed line makes a poor antenna look matched. A dummy load at the end of a very long, lossy cable would read almost 1:1 even with the load disconnected. Measure at the antenna end, or measure the cable's loss, before trusting a low SWR.
The power reflected by the antenna is not simply lost. With a matched transmitter or tuner it is re-reflected toward the antenna, and the real cost of a modest SWR is the extra cable loss on the way. The mismatch loss in the readouts is the power a transmitter with no tuner fails to deliver at that SWR.
Try this
- Set the SWR to 1.5 with 100 W. Return loss is 14.0 dB and 4.0 W comes back, a mismatch loss of only 0.18 dB.
- Set the SWR to 3.00 and the coax loss to 3 dB. The radio sees an SWR of only 1.67, and the antenna radiates 37.6 W of the 100 W.
- Set the SWR to 1.00. The envelope goes flat: no reflection, no standing wave.
A spectrum analyzer with a tracking generator measures return loss across a whole band at once through an external return-loss bridge or directional coupler. A vector network analyzer, such as the one built into the UTS3000A series, measures S11 directly and shows SWR, return loss, or impedance. The next explainer sweeps an antenna that way.
See the whole band, not one frequency. Signal analyzers with a built-in vector network analyzer.