LC resonance for homebrew builders

Every filter, oscillator, and antenna tuner in a kit comes down to an inductor and a capacitor that resonate at one frequency. The formula is short. The surprise for most builders is how far real parts are from their markings, and how much that moves the frequency.

Impedance of a parallel tank around its resonance (Q of 100, for illustration). Shaded strips are US amateur bands. The red span is where resonance can land with the part tolerance you set.

Resonant frequency
Inductance
Reactance at resonance
Band
Could land anywhere from

The formula

f = 1 ÷ (2π × √(L × C))  ·  toroid L (µH) = AL × turns² ÷ 10,000

At resonance the inductor's reactance, 2πfL, equals the capacitor's, 1 ÷ 2πfC, and they cancel. Frequency goes as one over the square root of L × C, so doubling either part lowers the frequency by a factor of 1.41, and a 5 % error in one part moves the frequency about 2.5 %.

Iron-powder toroids are specified by AL, here in µH per 100 turns. The values used above are the nominal figures from core makers' published tables: 49 for a T50-2, 40 for a T50-6, and 57 for a T68-2. AL varies from core to core and with how evenly the turns are spread, so the finished coil is the thing to measure.

Measure, then build

An LCR meter reads the actual inductance and capacitance of each part before it goes into the board. Measure a wound toroid, adjust the turns or squeeze them together, and measure again. A capacitor marked 100 pF can read 95 or 105, and a mica or C0G part holds its value with temperature better than a general-purpose ceramic. Measured at 100 kHz, a small air or iron-powder coil reads close to its value at HF, as long as you are well below its self-resonant frequency.

Try this

  • Set L to 4.7 µH and C to 100 pF. The tank resonates at 7.341 MHz, just above the 40 m band.
  • Pick a T50-2 with 20 turns. That is 1.96 µH; with 100 pF it lands at 11.37 MHz, between bands.
  • Raise the tolerance to ±10 % on each part. The resonance could fall anywhere across a span of about 20 %: measure, do not trust the markings.

UNI-T's UT622 LCR meters measure at 100 Hz to 10 kHz (UT622A) or 100 Hz to 100 kHz (UT622C and UT622E). To check the finished circuit at its working frequency, sweep it with a spectrum analyzer's tracking generator: a band-pass filter or a trap shows its centre frequency and shape directly.