Home » Learning Library » Setting FM Deviation with the Bessel Null, Interactive

Learning Library · Amateur radio · 6

Setting FM deviation with the carrier null

Frequency modulation does not change a transmitter's power, it moves it. As the deviation rises, power leaves the carrier and spreads into sidebands, and at certain exact ratios the carrier disappears completely. A spectrum analyzer can see that happen to within a fraction of a dB, which makes it a precise way to set deviation.

An FM transmitter modulated by a single audio tone, seen on a spectrum analyzer. Levels are in dBc relative to the unmodulated carrier. Sidebands sit at every multiple of the audio frequency.

Modulation index β
Carrier
Carson bandwidth
Sidebands above −40 dBc
Tone for the first null at this deviation

The modulation index

β = peak deviation ÷ audio frequency  ·  carrier = J0(β)  ·  n-th sidebands = Jn(β)

The carrier and every sideband pair follow Bessel functions of the modulation index β. The carrier term, J0, falls to exactly zero at β = 2.405, again at 5.520, and again at 8.654. At those points all of the transmitter's power is in the sidebands.

Carrier nullβTone for 5 kHzTone for 2.5 kHz
First2.4052,079 Hz1,040 Hz
Second5.520906 Hz453 Hz
Third8.654578 Hz289 Hz

The method

  • Pick the deviation you want and divide by 2.405 to get the audio tone. For 5 kHz that is 2,079 Hz.
  • Feed that tone into the transmitter's audio input from a function generator, starting at a low level.
  • Watch the carrier on the analyzer with a narrow resolution bandwidth and slowly raise the audio level. The carrier sinks; at the first null it drops into the noise. The deviation is now exactly 2.405 × 2,079 Hz = 5 kHz.

The null is sharp, so the method is precise, but it depends on the audio frequency being accurate, and it sets deviation for that tone. Many transmitters limit deviation on loud peaks; set the null at the level the limiter allows.

Try this

  • Press "Set up for 5 kHz", then raise the deviation slowly. At 5.00 kHz the carrier vanishes: β = 2.405.
  • Set 1,000 Hz and 5 kHz deviation. β is 5.00, the carrier is at −15.0 dBc, and the Carson bandwidth is 12 kHz.
  • Set 300 Hz and 6 kHz. β is 20 and the sidebands fill the screen: wide deviation with a low tone makes a very busy spectrum.

An analyzer with analog demodulation measures deviation directly, as a number. The AM/FM demodulation option (Optional) is available for the UTS3000T+ and UTS3000A series; the carrier-null method needs no option at all, only a clean tone and a narrow RBW.

See the null, not a needle. Spectrum analyzers and function generators for FM work.

Shop UNI-T spectrum analyzers

UNI-T Learning Library. Design. Debug. Deploy.™