Home » Learning Library » Two-Tone Test: SSB Linearity and IMD, Interactive

Learning Library · Amateur radio · 5

The two-tone test

An SSB transmitter has to be linear: what comes out should be a scaled copy of what goes in. Feed it two audio tones at once and any non-linearity shows up as new signals, intermodulation products, on either side of the tones. Those products are the splatter your neighbours on the band hear.

Top: the output spectrum around the carrier, in dB relative to peak envelope power (PEP), with tones at 700 Hz and 1,900 Hz. Bottom: the RF envelope on a scope; the grey curve is a perfectly linear amplifier. The amplifier is a smooth limiting model, for illustration.

IMD3, dB below PEP
IMD3, dB below one tone
IMD5, dB below PEP
Peak compression
Reading

Where the products land

Two tones at f1 and f2, spaced Δ apart, make third-order products at 2f1 − f2 and 2f2 − f1, one spacing outside each tone. Fifth-order products sit two spacings out, seventh-order three. With 700 Hz and 1,900 Hz tones, the third-order products fall at −500 Hz and 3,100 Hz, outside the speech channel and into the next one. Odd-order products land near the signal and no filter after the amplifier can remove them; even-order products land far away, where the low-pass filter does.

IMD3 at 2f1 − f2 and 2f2 − f1  ·  dB below PEP = dB below one tone + 6 dB

Read the reference. Two equal tones have a peak envelope power 6 dB above either tone, so the same product is 6 dB "better" quoted against PEP than against one tone. Equipment reviews use both; compare like with like.

Try this

  • Start at −10 dB drive on the well-behaved amplifier. IMD3 is −45 dB below PEP and the envelope arches are clean.
  • Drive to 0 dB, saturation. IMD3 rises to −28 dB below PEP, the peaks are compressed by 3.0 dB, and the tops of the arches flatten on the scope.
  • Switch to soft-limiting at −10 dB. It compresses earlier: IMD3 is −33 dB below PEP at a drive level where the other amplifier was clean.
  • Back off the drive in 2 dB steps and watch IMD3 fall about 4 dB per step and IMD5 about 8, the signature of third- and fifth-order distortion.

Running the test. A two-channel waveform generator gives two clean, stable audio tones; combine them with a simple resistive mixer and feed the microphone input at microphone level. Read IMD on a spectrum analyzer, through an attenuator sized for the transmitter's power. An oscilloscope on a sampled RF output shows the envelope: the same flattening that the analyzer measures in dB, seen as a shape.

Two tones in, the truth out. Two-channel waveform generators and spectrum analyzers.

Shop UNI-T waveform generators

UNI-T Learning Library. Design. Debug. Deploy.™