Learning Library · Amateur radio · 5
The two-tone test
An SSB transmitter has to be linear: what comes out should be a scaled copy of what goes in. Feed it two audio tones at once and any non-linearity shows up as new signals, intermodulation products, on either side of the tones. Those products are the splatter your neighbours on the band hear.
Top: the output spectrum around the carrier, in dB relative to peak envelope power (PEP), with tones at 700 Hz and 1,900 Hz. Bottom: the RF envelope on a scope; the grey curve is a perfectly linear amplifier. The amplifier is a smooth limiting model, for illustration.
Where the products land
Two tones at f1 and f2, spaced Δ apart, make third-order products at 2f1 − f2 and 2f2 − f1, one spacing outside each tone. Fifth-order products sit two spacings out, seventh-order three. With 700 Hz and 1,900 Hz tones, the third-order products fall at −500 Hz and 3,100 Hz, outside the speech channel and into the next one. Odd-order products land near the signal and no filter after the amplifier can remove them; even-order products land far away, where the low-pass filter does.
Read the reference. Two equal tones have a peak envelope power 6 dB above either tone, so the same product is 6 dB "better" quoted against PEP than against one tone. Equipment reviews use both; compare like with like.
Try this
- Start at −10 dB drive on the well-behaved amplifier. IMD3 is −45 dB below PEP and the envelope arches are clean.
- Drive to 0 dB, saturation. IMD3 rises to −28 dB below PEP, the peaks are compressed by 3.0 dB, and the tops of the arches flatten on the scope.
- Switch to soft-limiting at −10 dB. It compresses earlier: IMD3 is −33 dB below PEP at a drive level where the other amplifier was clean.
- Back off the drive in 2 dB steps and watch IMD3 fall about 4 dB per step and IMD5 about 8, the signature of third- and fifth-order distortion.
Running the test. A two-channel waveform generator gives two clean, stable audio tones; combine them with a simple resistive mixer and feed the microphone input at microphone level. Read IMD on a spectrum analyzer, through an attenuator sized for the transmitter's power. An oscilloscope on a sampled RF output shows the envelope: the same flattening that the analyzer measures in dB, seen as a shape.
Two tones in, the truth out. Two-channel waveform generators and spectrum analyzers.
Shop UNI-T waveform generatorsUNI-T Learning Library. Design. Debug. Deploy.™