Is my transmitter clean?

Every transmitter also puts out a little energy at 2, 3, 4, and 5 times its frequency. The FCC sets how little. A spectrum analyzer shows the harmonics directly, as long as the analyzer is not adding harmonics of its own.

Levels in dBc, dB relative to the fundamental. The dashed line is the Part 97 limit for the band. Harmonic levels, the filter's attenuation, and the analyzer's distortion are illustrative, not measurements of any particular radio or analyzer.

Verdict on screen
Worst harmonic shown
Part 97 limit
Transmitter's own worst
Noise floor
The 10 dB test

The limits

FCC Part 97, section 97.307, sets the limits as the mean power of any spurious emission relative to the mean power of the fundamental:

Transmitter frequencySpurious emissions must be at least
Below 30 MHz (transmitters installed after January 1, 2003)43 dB below the fundamental
30 to 225 MHz60 dB below the fundamental. A transmitter of 25 W or less may instead keep them at or below 25 µW and at least 40 dB down

Section 97.307 also requires spurious emissions to be reduced "to the greatest extent practicable", and older transmitters have different figures. Read the section itself for your case. A dB, decibel, is a power ratio, and dBc is decibels relative to the carrier, the fundamental.

Where harmonics come from, and where they go

A power amplifier is not perfectly linear, so it makes harmonics, and more of them when it is driven into compression. The low-pass filter on the output is what brings them under the limit. Bypass it, or select the wrong band filter, and the harmonics show up at full strength.

The analyzer's own input mixer is also not perfectly linear. Drive it too hard and it creates harmonics of the fundamental that land exactly where the transmitter's harmonics would be. The analyzer cannot tell you which is which, but one test can: add 10 dB of input attenuation. A real harmonic stays at the same dBc. A harmonic the analyzer made drops, by about 10 dB for a second harmonic and 20 dB for a third.

Try this

  • On 40 m at 100 % drive, bypass the filter. The third harmonic at −20 dBc is 23 dB over the 43 dB limit, and the 10 dB test confirms it is real.
  • Put the filter back in and pick 2 m. With −10 dBm at the mixer, the screen shows a second harmonic at −50 dBc, over the 60 dB limit, and the 10 dB test says the analyzer made it.
  • Lower the mixer level to −30 dBm. The second harmonic now reads −69 dBc and passes, but the 10 dB test says most of it is still the analyzer. At −50 dBm the line stays put when tested: −75 dBc is the transmitter's own.
  • Back on 40 m with the filter in, drive to 130 %. Compression raises every harmonic: the third by 12 dB, the second by 6 dB.

Before any of this, the transmitter's power has to come down to a level the analyzer can take: a dummy load with a sampling port, or a power attenuator, as in the first explainer of this group. Lowering the mixer level lowers distortion but raises the noise floor relative to the signal, so there is a best setting in between. For harmonics above an oscilloscope's comfort zone, see scope FFT vs. spectrum analyzer.